Universal field matching in craniospinal irradiation by a background-dose gradient-optimized method.

J Appl Clin Med Phys. 2018 Jan;19(1):46-49 Epub 2017 Nov 7.

Traneus E1Bizzocchi N2Fellin F2Rombi B2Farace P2.

1   RaySerach Laboratories, Stockholm, Sweden.

2   Proton therapy Unit, Hospital of Trento, Trento, Italy.

 

Abstract

PURPOSE:

The gradient-optimized methods are overcoming the traditional feathering methods to plan field junctions in craniospinal irradiation. In this note, a new gradient-optimized technique, based on the use of a background dose, is described.

METHODS:

Treatment planning was performed by RayStation (RaySearch Laboratories, Stockholm, Sweden) on the CT scans of a pediatric patient. Both proton (by pencil beam scanning) and photon (by volumetric modulated arc therapy) treatments were planned with three isocenters. An 'in silico' ideal background dose was created first to cover the upper-spinal target and to produce a perfect dose gradient along the upper and lower junction regions. Using it as background, the cranial and the lower-spinal beams were planned by inverse optimization to obtain dose coverage of their relevant targets and of the junction volumes. Finally, the upper-spinal beam was inversely planned after removal of the background dose and with the previously optimized beams switched on.

RESULTS:

In both proton and photon plans, the optimized cranial and the lower-spinal beams produced a perfect linear gradient in the junction regions, complementary to that produced by the optimized upper-spinal beam. The final dose distributions showed a homogeneous coverage of the targets.

DISCUSSION:

Our simple technique allowed to obtain high-quality gradients in the junction region. Such technique universally works for photons as well as protons and could be applicable to the TPSs that allow to manage a background dose.

HOW CAN WE HELP YOU?
Name
Vorname
Ihre Email-Adresse
Telefon
Ihre Anfrage
Provincia autonoma di Trento, in conformità con l'art. 13 della Legge 196/2003 e successive modifiche, dichiara che i dati personali qui raccolti hanno finalità di registrare l'utente, attivare nei suoi confronti il servizio richiesto e fornirgli informazioni sull'attività ed i servizi del Centro di Protonterapia, nonché sulle iniziative e le attività promosse dallo stesso. Tali dati verranno trattati elettronicamente in conformità con le leggi vigenti; si garantisce la riservatezza degli stessi e che non saranno oggetto di comunicazione o diffusione a terzi. L'interessato può esercitare in qualsiasi momento i diritti di cui all'art. 7 della suddetta legge (accesso correzione e cancellazione dei dati), rivolgendosi a Provincia autonoma di Trento, uff.informazioni@provincia.tn.it.
PROTON THERAPY CENTRE - TRENTO
ADRESSE:
Via Al Desert n.14, 38123 Trento

MAIL:
protonterapia@apss.tn.it

TELEFON:
+39 0461 1953100

Öffnungszeiten: Lun - Ven | 8.30 - 16.00